Backflow Testing in Glendale, CA

7 licensed providers · NFPA 10 compliant · Updated March 2026

Glendale enforces NFPA 10 with local amendments that go beyond the CA state code. These jurisdiction-specific changes to Glendale adopts the 2025 CFC with limited local clarifications to administrative provisions; no additional local amendments specific to NFPA 10 beyond state-level California amendments directly affect backflow testing requirements for building owners and property managers in Glendale.

Who Is Your AHJ for Backflow Testing in Glendale?

The Authority Having Jurisdiction (AHJ) for backflow testing in Glendale is the Glendale Fire Department, Fire Prevention Bureau. The AHJ reviews inspection reports, issues violations, and has final authority over fire code interpretation in Glendale.

Your Authority Having Jurisdiction (AHJ)

Authority Having Jurisdiction
Glendale Fire Department, Fire Prevention Bureau
Fire Marshal
Jovan Diaz
Portal Fee Range
No third-party portal filing fees; standard city permit and inspection fees apply per the Glendale fee schedule
Portal Notes
Glendale does not use a third-party reporting portal. Reports are submitted directly to the Fire Prevention Bureau. Accepted report types: fire sprinkler, fire alarm, standpipe, fire pump, fire extinguisher, kitchen hood suppression.

What Code Does Glendale Enforce?

Glendale enforces NFPA 10 (2022 edition) through the 2025 California Fire Code (Title 24 CCR Part 9, Chapter 80) adopts NFPA 10, 2022 edition, with California amendments; effective January 1, 2026 (based on the IFC 2024 §906.1 references NFPA 10 for portable fire extinguisher installation, maintenance, and use with California requires monthly (30-day) inspections by the building owner, occupant, or authorized agent per CCR Title 19 §574.1 — electronic monitoring is accepted as an alternative. All maintenance and service must be performed by a State Fire Marshal-licensed fire extinguisher concern per H&S Code §13160. Verification of Service Collars must be attached after any maintenance involving internal examination or recharging per CCR Title 19 §596. California requires Class K extinguishers within 30 feet of commercial cooking operations per CCR Title 19 §573.).

Penalties for Non-Compliance

Penalties by violation type
FrequencySeverityPenalty
annualmediumAdministrative citation per Glendale Water and Power cross-connection control program.

Licensed Backflow Testing Contractors in Glendale

Reyes Engineering

5/5 (1 reviews)

(818) 240-4060

Visit website

Caspian Commercial Plumbing

5/5 (3 reviews)

(818) 649-2500

Visit website

Techno - Advanced

5/5 (1 reviews)

+1 818-248-6300

Visit website

Frequently Asked Questions

How often is backflow testing required in Glendale?

Glendale requires backflow testing once per year per California Health and Safety Code §116800; Glendale Water and Power Cross-Connection Control Program. The deadline type is anniversary, with a deadline of 12 months from installation or last test.

Who is the AHJ for backflow testing in Glendale?

The Authority Having Jurisdiction (AHJ) for backflow testing in Glendale is the Glendale Fire Department, Fire Prevention Bureau. The AHJ reviews inspection reports, issues violations, and has final authority over code interpretation. Contact the fire marshal, Jovan Diaz, for questions.

What happens if I miss a backflow testing deadline in Glendale?

Missing a backflow testing deadline in Glendale can result in Administrative citation per Glendale Water and Power cross-connection control program. The penalty severity is classified as medium.

What edition of NFPA 10 does Glendale enforce?

Glendale enforces the 2022 edition of NFPA 10. This matches the current published edition. Adopted through 2025 California Fire Code (Title 24 CCR Part 9, Chapter 80) adopts NFPA 10, 2022 edition, with California amendments; effective January 1, 2026.

Data current as of March 2026